Push-button ignition switch does not operate
Description
Check that vehicle is under the condition shown in “Conditions of vehicle” before starting diagnosis, and check each symptom.
Note:
The engine start function, door lock function, power distribution system, and nats-ivis/nvis in the intelligent key system are closely related to each other regarding control. The vehicle security function can operate only when the door lock and power distribution system are operating normally.
Conditions of vehicle (operating conditions)
Diagnosis procedure
1.Perform work support
Perform “inside ant diagnosis” on work support of “intelligent key”.
Refer to pcs-66, "intelligent key : consult function (bcm - intelligent key)".
>> Go to 2.
2.Perform self-diagnosis result
Perform self-diagnosis result of “bcm”.
Is dtc detected? Yes >> refer to bcs-49, "dtc index".
No >> go to 3.
3.Check push-button ignition switch
Check push-button ignition switch.
Refer to pcs-98, "component function check".
Is the operation normal? Yes >> go to 4.
No >> repair or replace malfunctioning parts.
4.Confirm the operation
Confirm the operation again.
Is the inspection normal? Yes >> check intermittent incident. Refer to gi-39, "intermittent incident".
No >> go to 1.
P1226 TP Sensor
DTC Logic
DTC DETECTION LOGIC
DTC No.
CONSULT screen terms
(Trouble diagnosis content)
DTC detecting condition
Possible cause
P1226
CTP LEARNING-B1
(CTP LEARNING-B1)
Closed throttle position learning is not performed
successfully, repeatedly.
Electric thr ...
High-mounted stop lamp
Removal and Installation
HIGH-MOUNTED STOP LAMP - WITH REAR SPOILER
Removal
Remove the rear air spoiler. Refer to EXT-46, "Removal and
Installation".
Remove the screws and the high-mount stop lamp from the rear air
spoiler.
Installation
Installation is in the reverse or ...
Ipdm-e branch line circuit
Diagnosis Procedure
1.Check connector
Turn the ignition switch off.
Disconnect the battery cable from the negative terminal.
Check the terminals and connectors of the ipdm e/r for damage, bend and
loose connection (unit side
and connector side).
Is the inspection result normal?
Yes ...