Description
When replacing ECM, the following procedure must be performed. (For details, refer to EC-135, "Work Procedure".)
PROGRAMMING OPERATION
NOTE:
After replacing with a blank ECM, programming is required to write ECM information. Be sure to follow the procedure to perform the programming.
Work Procedure
1.SAVE ECM DATA
With CONSULT
NOTE:
>> GO TO 2.
2.CHECK ECM PART NUMBER
Check ECM part number to see whether it is blank ECM or not.
NOTE:
Is the ECM a blank ECM? YES >> GO TO 3.
NO >> GO TO 5.
3.SAVE ECM PART NUMBER
Read out the part number from the old ECM and save the number, following the programming instructions.
Refer to CONSULT Operation Manual.
NOTE:
>> GO TO 4.
4.PERFORM ECM PROGRAMMING
After replacing ECM, perform the ECM programming. Refer to CONSULT Operation Manual.
NOTE:
>> GO TO 6.
5.REPLACE ECM
Replace ECM. Refer to EC-485, "Removal and Installation".
>> GO TO 6.
6.PERFORM INITIALIZATION OF IVIS (NATS) SYSTEM AND REGISTRATION OF ALL IVIS (NATS) IGNITION KEY IDS
Refer to SEC-61, "ECM : Work Procedure" (With Intelligent Key System) or SEC-174, "ECM : Work Procedure" (Without Intelligent Key System).
>> GO TO 7.
7.CHECK ECM DATA STATUS
Check if the data is successfully copied from the ECM at Step 1 (before replacement) and saved in CONSULT.
Is the data saved successfully? YES >> GO TO 8.
NO >> GO TO 9.
8.WRITE ECM DATA
With CONSULT
NOTE:
The data saved by “SAVING DATA FOR REPLC CPU” is written to ECM.
>> GO TO 10.
9.PERFORM VIN REGISTRATION
Refer to EC-137, "Work Procedure".
>> GO TO 10.
10.PERFORM ACCELERATOR PEDAL RELEASED POSITION LEARNING
Perform Accelerator Pedal Released Position Learning. Refer to EC-138, "Work Procedure".
>> GO TO 11.
11.PERFORM THROTTLE VALVE CLOSED POSITION LEARNING
Perform Throttle Valve Closed Position Learning. Refer to EC-139, "Work Procedure".
>> GO TO 12.
12.PERFORM IDLE AIR VOLUME LEARNING
Perform Idle Air Volume Learning. Refer to EC-140, "Work Procedure".
>> END
Unit removal and installation
TRANSMISSION ASSEMBLY
Exploded View
Transaxle assembly
O-ring
CVT fluid charging pipe
CVT fluid charging pipe cap
Tightening must be done following the installation procedure. Refer to
TM-283, "Removal and Installation".
: Always replace after every
disassemb ...
Symptom diagnosis
The eco mode indicator lamp does not turn on
Description
The ECO mode indicator lamp does not turn ON when the ECO mode switch is
operated.
Diagnosis Procedure
1.Perform combination meter on board diagnosis
Perform combination meter on board diagnosis. Refer to MWI-16, "Description" ...
Dtc/circuit diagnosis
Power supply and ground circuit
Audio unit
Audio unit : diagnosis procedure
Regarding Wiring Diagram information, refer to AV-157, "Wiring Diagram".
1.Check fuse
Are the fuses blown?
Yes >> replace the blown fuse after repairing the affected circuit.
No >> go to 2.
...