Component Function Check
1.CHECK VDC OFF SWITCH OPERATION
Check that VDC OFF indicator lamp in combination meter turns ON/OFF when VDC OFF switch is operated.
Is the inspection result normal? YES >> Inspection End.
NO >> Proceed to diagnosis procedure. Refer to BRC-92, "Diagnosis Procedure".
Diagnosis Procedure
Regarding Wiring Diagram information, refer to BRC-44, "Wiring Diagram".
1.CONNECTOR INSPECTION
Turn ignition switch OFF.
Disconnect ABS actuator and electric unit (control unit) and VDC OFF switch connectors.
Check connectors and terminals for deformation, disconnection, looseness or damage.
Is the inspection result normal? YES >> GO TO 2.
NO >> Repair or replace as necessary.
2.CHECK VDC OFF SWITCH
Check VDC OFF switch. Refer to BRC-93, "Component Inspection".
Is the inspection result normal? YES >> GO TO 3.
NO >> Replace VDC OFF switch. Refer to BRC-112, "Removal and Installation".
3.Check VDC OFF Switch signal
With CONSULT.
Connect ABS actuator and electric unit (control unit) and VDC OFF switch connectors.
Turn ignition switch ON.
In “DATA MONITOR” select “OFF SW” and check VDC OFF switch signal.
Is the inspection result normal? YES >> Refer to BRC-51, "Work Flow".
NO >> GO TO 4.
4.Check VDC OFF Switch circuit
Turn ignition switch OFF.
Disconnect ABS actuator and electric unit (control unit) and VDC OFF switch connectors.
Check continuity between ABS actuator and electric unit (control unit) connector E33 terminal 15 and VDC OFF switch connector M64 terminal 6.
Check continuity between ABS actuator and electric unit (control unit) connector terminal E33 terminal 15 and ground.
Is the inspection result normal? YES >> GO TO 5.
NO >> Repair or replace malfunctioning components.
5.Check vdc off switch ground circuit
Check continuity between VDC OFF switch connector M64 terminal 8 and ground.
Is the inspection result normal? YES >> Replace ABS actuator and electric unit (control unit). Refer to BRC-110, "Removal and Installation".
NO >> Repair or replace malfunctioning components.
Component Inspection
1.Check vdc off switch
Turn ignition switch OFF.
Disconnect VDC OFF switch connector.
Check continuity between terminals of VDC OFF switch connector.
Is the inspection result normal? YES >> Inspection End.
NO >> Replace VDC OFF switch. Refer to BRC-112, "Removal and Installation".
How to set srt code
Description
OUTLINE
In order to set all SRTs, the self-diagnoses as in the “SRT ITEM” table must
have been performed at least
once. Each diagnosis may require actual driving for a long period of time under
various conditions.
SRT ITEM
The table below shows required self-diagnostic ...
Removal and installation
EXHAUST SYSTEM
Exploded View
Sub muffler
Spring
Mounting rubber
Seal bearing
Catalyst shroud (upper)
Seal bearing
Exhaust front tube
Spring
Catalyst shroud (lower)
Clamp
Heated oxygen sensor 2
Ring gasket
Mounting rubber
Main muffler
Exhaust finisher (if equipped ...
Front combination lamp
Exploded View
Large cover (not serviceable)
Small cover (not serviceable)
Front combination lamp
Halogen lamp bulb (high beam)
Turn signal lamp bulb
Turn signal lamp bulb socket
LED harness connector
Halogen lamp bulb (high beam)
harness connector
Halogen lamp bulb (low bea ...