Diagnosis procedure
1.Check connector
Is the inspection result normal? YES >> GO TO 2.
NO >> Repair the terminal and connector.
2.Check harness for open circuit
Is the measurement value within the specification? Yes >> go to 3.
No >> repair the bcm branch line.
3.Check power supply and ground circuit
Check the power supply and the ground circuit of the bcm. Refer to the following.
Is the inspection result normal? YES (Present error)>>Replace the BCM. Refer to the following.
YES (Past error)>>Error was detected in the BCM branch line.
NO >> Repair the power supply and the ground circuit.
Wiring diagram
Manual air conditioning system
Wiring Diagram
Manual heater system
Wiring Diagram
...
Glove box lamp
Removal and installation
Warning:
Do not touch bulb while it is lit or right after being turned off.
Burning may result.
Caution:
Do not touch glass surface of the bulb with bare hands or allow oil or
grease to get on it to prevent
damage to bulb.
Removal
Remove the glove box assembly ...
L terminal circuit (open)
Description
The “L” terminal circuit controls the charge warning lamp. The charge warning
lamp turns ON when the ignition
switch is set to ON or START. When the generator is providing sufficient voltage
with the engine running,
the charge warning lamp turns OFF. If the charge warnin ...